The SmartSolar MPPT RS solar charge controllers are Victron's solution for systems with large series connected PV arrays charging 48V DC battery banks. This product is perfect for large off-grid, and grid connected battery systems.

Available in a 5.76kW and 11.52kW model, features include a wide 65-450 VDC operating solar voltage input, independent tracking inputs, full connectivity, isolated PV connections, display screen, fully programmable battery charging parameters and active cooling. The new metal case design and fully covered electrical connections improve the safety and modernise the presentation in line with the latest suite of Victron products.

Ultra-fast Maximum Power Point Tracking (MPPT) Solar Charge Controller
The MPPT RS SmartSolar is a 48 V Solar charge controller with up to 450 VDC PV input and either 100 A, or 200 A output. It is used in on-grid and off-grid solar applications where maximum battery charging power is required.

Multiple independent MPPT tracking inputs
With multiple MPPT trackers, you can optimize your solar panel design for maximum performance for your
specific location.

Isolated PV connections for additional safety
Full galvanic isolation between PV and battery connections provide additional overall system safety.

Wide MPPT voltage range
65 – 450 VDC PV operating range, with a 120 VDC PV startup voltage.

Light weight, efficient and quiet
Thanks to high frequency technology and a new design this powerful charger weighs only 7.9 kg for the 100 A model. In addition to this it has an excellent efficiency, low standby power, and a very quiet operation.

Display and Bluetooth
The display reads battery, and controller parameters. The parameters can be accessed with a smartphone or other Bluetooth enabled device. In addition, Bluetooth can be used to set up the system and to change settings with VictronConnect.

PV Isolation resistance monitoring for peace of mind at higher voltages
The MPPT RS continuously monitors the PV array and can detect if there are faults that reduce the isolation
of the panels to unsafe levels.

VE.Can and VE.Direct port
For connection to a GX device for system monitoring, data logging, and remote firmware updates. VE.Can allows for up to 25 units to be connected together in parallel and synchronize their charging.

I/O Connections
Programmable Relay, temperature sensor, auxiliary, digital input and voltage sensor connections. The remote input can accept the Victron smallBMS, and other BMS with allow-to-charge signal

Model 450/100
Battery voltage 48 V
Rated charge current 100 A
Maximum charge power 5.8 kW at 57.6 V
Charge voltage 'float' Default setting: 55.2 V (adjustable)
Charge voltage 'absorption’ Default setting: 57.6 V (adjustable)
Programmable voltage range (7) Minimum: 36 V
Maximum: 60 V
Charge algorithm Multi-stage adaptive (adjustable)
Battery temperature sensor Included
Maximum efficiency 96 %
Self-consumption 15 mA
Maximum DC PV voltage 450 V
Start-up voltage 120 V
MPPT operating voltage range (1) 65 – 450 V
Number of trackers 2
Max. PV operational input current MC4 models: 16 A per tracker
Tr models: 18 A per tracker
Max. PV short circuit current (2) 20 A per tracker
Max. DC output charging power 4000 W per tracker
5760 W total
Maximum PV array size per tracker (3) 7200 Wp (450 V x 20 A)
PV Isolation fail level 100 kΩ
Synchronised Parallel Operation Yes, up to 25 units with VE.Can
Programmable relay (5) Yes
Protection PV reverse polarity
Output short circuit
Over temperature
Data communication (6) VE.Direct port, VE.Can port & Bluetooth (6)
Bluetooth frequency 2402 – 2480 MHz
Bluetooth power 4dBm
General purpose analogue/digital in port Yes, 2x
Remote on-off Yes
Operating temperature range -40 to +60 °C (fan assisted cooling)
Humidity (non-condensing) max 95 %
Material & Colour steel, blue RAL 5012
Protection category IP21
Battery-connection M8 bolts
Power terminals PV input (-Tr version) 16 mm2
Power terminals PV input (MC4 version) 1 pair of male and female MC4 connectors
per tracker
Weight 7.9 kg
Dimensions (h x w x d) in mm 440 x 313 x 126
  1. MPPT operating voltage range is constrained by battery voltage - PV VOC should not exceed 8 x
    battery float voltage. For example, a 52,8 V float voltage results in a maximum PV VOC of 422,4 V. See
    product manual for further information..
  2. A higher short circuit current may damage the controller if PV array is connected in reverse polarity.
  3. Max. 450 VOC result in appr. 360 Vmpp, therefor the maximum PV array is appr. 360 V x 20 A = 7200
    Wp.
  4. The MPPT RS will test for sufficient resistive isolation between PV+ and GND, and PV- and GND. In the
    event of a resistance below the threshold, the unit will stop charging, display the error, and send the
    error signal to the GX device (if connected) for audible and email notification.
  5. Programmable relay which can be set for general alarm, DC under voltage or genset start/stop function. DC rating: 4 A up to 35 VDC and 1 A up to 70 VDC
  6. The MPPT RS is currently not compatible with VE.Smart Networks.
  7. The Charger set-point (float and absorption) can be set to max 60 V. The output voltage at the charger terminals can be higher, due to temperature compensation as well as compensation for voltage drop over the battery cables. The maximum output current is reduced on a linear basis from full current at 60 V to 5A at 62 V. The equalization voltage can be set to max 62V, the equalization current percentage can be set to max 6%.

 

 

SKU 8719076049319
Barcode # SCC145110410
Brand Victron
Shipping Weight 10.0000kg
Shipping Width 0.220m
Shipping Height 0.400m
Shipping Length 0.540m
Shipping Cubic 0.047520000m3

Be The First To Review This Product!

Help other The 12 Volt Shop users shop smarter by writing reviews for products you have purchased.

Write a product review