Marine wire and cable are the cables for applications in the marine, including seas and oceans. These cables have excellent water resistance, in particular saltwater. To ensure such protection, most marine copper cables use tinned copper conductors

AUSTRALIAN MADE MARINE TINNED CABLE

Here at The 12 Volt Shop, we supply high-grade Marine Tinned Cables engineered to AS/NZS standards for harsh saltwater, offshore, and high-humidity environments. Our range features premium Tycab (Tyree) tinned oxygen-free copper cables for sizes under 0 B&S (50.00mm²) to resist internal oxidation and black wire rot, and heavy-duty Elcon SDI (Single Core Double Insulated) Rubber Flexible Power Cables (NSGAFÖU 1.9/3.3kV) for 0 B&S up to 4/0 B&S (120mm²) high-amperage feeds.

Selecting the correct cable thickness is critical to marine safety and continuous operational performance. A common misconception is that short cable runs allow you to exceed a cable's continuous current rating. While short runs keep voltage drop low, they do not increase the physical heat capacity of the conductor—overloading a short cable generates rapid heat buildup, creating a serious fire hazard in enclosed boat compartments.

Real-world marine cable selection must account for AS/NZS 3008 and JASO D609 thermal de-rating factors, including conductor bundling and elevated ambient temperatures inside engine rooms, battery compartments, or enclosed helm consoles.

To calculate voltage drop and minimum wire gauge for specific run lengths, you can download the free Victron Toolkit App or refer to our detailed technical guide below:

Download Victron Toolkit APP  |  Read Our Complete Technical Guide to Cable & Fuse Selection

Cable Size Nominal Area (mm²) Cable Spec / Sheath Type Catalog Max (1 Cable @ 30°C)* 2 Touching Cables (0.80 Factor) 50°C Engine/Console (0.76 Factor) 2 Cables @ 50°C (0.608 Combined Factor)
3mm Marine Tinned 1.13mm² Tycab Tinned Marine 20A 16.0A 15.2A 12.1A
4mm Marine Tinned 1.84mm² Tycab Tinned Marine 28A 22.4A 21.2A 17.0A
5mm Marine Tinned 2.90mm² Tycab Tinned Marine 37A 29.6A 28.1A 22.5A
6mm Marine Tinned 4.59mm² Tycab Tinned Marine 48A 38.4A 36.4A 29.1A
8 B&S Marine Tinned 7.92mm² Tycab Tinned Marine 74A 59.2A 56.2A 45.0A
6 B&S Marine Tinned 13.57mm² Tycab Tinned Marine 103A 82.4A 78.2A 62.6A
4 B&S Marine Tinned 20.29mm² Tycab Tinned Marine 135A 108.0A 102.6A 82.0A
3 B&S Marine Tinned 25.73mm² Tycab Tinned Marine 168A 134.4A 127.6A 102.1A
2 B&S Marine Tinned 32.15mm² Tycab Tinned Marine 188A 150.4A 142.8A 114.3A
0 B&S (SDI50-3.3kV) 50.00mm² Elcon SDI NSGAFÖU Rubber 270A 216.0A 205.2A 164.2A
00 B&S (SDI70-3.3kV) 70.00mm² Elcon SDI NSGAFÖU Rubber 340A 272.0A 258.4A 206.7A
000 B&S (SDI95-3.3kV) 95.00mm² Elcon SDI NSGAFÖU Rubber 410A 328.0A 311.6A 249.3A
4/0 B&S (SDI120-3.3kV) 120.00mm² Elcon SDI NSGAFÖU Rubber 487A 389.6A 370.1A 296.1A

* AMP RATING: Based on free air baseline ratings to AS/NZS 3008 standards[cite: 2]. Real-world continuous capacity must be de-rated when bundled or operated inside warm engine compartments and console enclosures[cite: 1].

NOTE: Roll quantities offer lower per-metre costs and reduced freight rates compared to purchasing cut lengths per metre.